These are small devices that are surgically placed inside the body, usually under the skin near the collarbone. They constantly monitor the heart's rhythm. If the heart starts beating too fast or irregularly in a dangerous way (like ventricular fibrillation), the device automatically sends a shock to correct it. They are used for people with heart conditions that make them prone to these dangerous rhythms.
Every report comes from a Lived member, sent anonymously.
Have you had Implantable Cardioverter Defibrillators for Heart Failure?
An implantable cardioverter defibrillator (ICD) is a small battery-powered device placed under the skin of the chest that watches the heart's rhythm around the clock. If it detects a dangerously fast rhythm starting in the heart's lower chambers, called ventricular tachycardia or ventricular fibrillation, it delivers an electrical shock to reset the heart to a normal beat. These rhythms are the usual cause of sudden cardiac arrest, which is fatal within minutes unless the rhythm is stopped. Most ICDs can also work as a pacemaker, sending small painless pulses when the heart beats too slowly or to break up some fast rhythms without a full shock. An ICD is recommended for people at high risk of sudden death from these rhythms. That includes people who have already survived a cardiac arrest or a dangerous ventricular rhythm, and people whose heart muscle is weakened and pumps poorly after heart attacks or from heart failure or cardiomyopathy (disease of the heart muscle), even if they have never had an arrhythmia. Some inherited or structural conditions can also qualify, such as hypertrophic cardiomyopathy (an inherited thickening of the heart muscle), inherited electrical disorders like Brugada syndrome and certain forms of long QT syndrome, congenital heart disease, and cardiac sarcoidosis (inflammation that can scar the heart muscle). ICDs are used in children as well as adults. The benefit is protection, not repair. In randomized trials of people with weakened hearts, deaths from any cause over about three years fell from roughly 28 in 100 with usual care to about 21 in 100 with an ICD, and sudden deaths fell from about 12 in 100 to about 4 in 100. An ICD does not treat the underlying heart disease or stop arrhythmias from happening, so heart medicines and other treatments continue. There are several types. A transvenous ICD, the most common, has one or more wires (leads) that run through a vein into the heart. A subcutaneous ICD keeps its single lead under the skin of the chest, outside the heart; it can shock but cannot pace, and may suit younger people, those at higher infection risk or those who do not need pacing. A cardiac resynchronization defibrillator (CRT-D) adds a lead that helps both lower chambers beat together, for some people with advanced heart failure. When the risk is expected to be temporary, such as soon after a heart attack or while heart function may recover, a wearable defibrillator vest is sometimes used instead while the decision is made.
The decision usually follows heart testing, often an electrocardiogram (ECG, a recording of the heart's electrical activity) and an echocardiogram (an ultrasound of the heart), along with blood tests. The cardiologist should discuss which type of device fits, whether pacing is needed, and the benefits and trade-offs for you specifically. Bring a full list of prescription and over-the-counter medicines and supplements. Blood thinners matter most, because they raise the chance of bleeding around the device, and the team will say whether to continue, adjust or pause them; do not stop one on your own. Mention diabetes, kidney disease, allergies, and any cold, fever or other illness in the days before, since an active infection can delay the procedure. You will usually be asked not to eat or drink for several hours beforehand. Some centers ask you to wash with a special antiseptic soap the night before. Plan for someone to drive you home, because driving is restricted after an ICD is placed.
Implantation is done in a hospital, usually by a cardiologist or surgeon. Most people are awake but given medicine to relax, plus local anesthetic to numb the skin below the collarbone; some receive general anesthesia. Antibiotics are often given to lower infection risk. For a transvenous ICD, the doctor makes a small cut below the collarbone, usually on the left, guides the leads through a vein into the heart using X-ray imaging, and connects them to the generator, which is tucked into a pocket under the skin or muscle. A subcutaneous ICD is placed on the side of the chest below the armpit, with its lead running under the skin. The device is tested and programmed before the incision is closed. The procedure typically takes about two to three hours.
Many people stay in the hospital overnight. A chest X-ray and ECG confirm that the leads are in place and the device is working, and its settings are checked before you leave. Soreness, bruising and tiredness around the incision are common for the first days, and most people return to light daily activities within a few days. For the first several weeks the main goal is to let the leads settle into place. Teams commonly advise avoiding heavy lifting (often more than 10 to 15 pounds), pushing, pulling and raising the arm on the device side above the shoulder, with fuller activity after about four to six weeks. Keep the incision clean and dry and follow the team's instructions on showering. Instructions vary, so follow your own team's. Driving rules depend on why the ICD was placed and on local law. When the device was implanted to prevent a first cardiac arrest, a wait of about a week is often advised; many US states require six months without driving after an ICD placed for a prior cardiac arrest or dangerous arrhythmia, and again after a shock. Commercial driving is generally not allowed. Follow-up usually starts about a month after implant and continues at least every six months, often with a home monitor or app that sends device data to the clinic. Batteries generally last about five to seven years, depending on the device and how often it paces or shocks, after which another procedure replaces the device, and sometimes the leads. Carry the device ID card, tell every clinician and dentist about the ICD, keep phones and earbuds at least 6 inches from it, and check before any MRI, since many newer devices allow scans with precautions. Most people can exercise, though full-contact sports that could damage the device may be off limits. A high-energy shock lasts under a second and often feels like a hard kick to the chest. If you get one shock and feel well afterward, call your care team; they will usually want to see you that day or the next. Call 911 right away if you feel several strong shocks in a short time, if symptoms such as chest pain, trouble breathing or confusion do not go away after a shock, or if you faint or collapse. If a person with an ICD collapses and is unresponsive, others should call 911 and start CPR. Call the care team promptly for a fever in the days and weeks after implant, or for swelling, bleeding, drainage or worsening redness at the incision. Dizziness, lightheadedness, shortness of breath or palpitations that come and go are also worth reporting.
ICD implantation is generally safe, but it is surgery with a permanent device. Bruising and swelling at the site are common; bleeding at the site is more likely in people taking blood thinners. Infection of the incision, the device or the leads is less common but serious, because it can spread to other parts of the body and can mean the device and leads have to be removed. Placing leads through a vein can rarely puncture a lung or injure a blood vessel or the heart, and a lead can shift out of position or break over time, sometimes requiring another procedure. Subcutaneous ICDs avoid most lead problems inside the heart but can cause discomfort or skin irritation over the device. Unneeded shocks are a practical concern. The device can mistake a fast but harmless rhythm, such as a racing heart during hard exercise, or a damaged lead's signal for a dangerous one. Unneeded shocks are more common in the early months and can usually be reduced by reprogramming or medicine. Recalls of specific models also happen, so it is reasonable to ask at check-ups whether any affect your device. Living with an ICD can bring anxiety, depression or, after shocks, symptoms of post-traumatic stress, and these deserve attention just as much as the device. If health declines near the end of life, the shock function can be turned off without surgery; discussing this ahead of time is part of advance care planning.
Last reviewed • Oct 2026
Educational content, not medical advice.
My defib has been emitting a high urgency alert tone every 3 hours. 40 minutes after the hour. For 3 or 4 months now. I've been in the hospital. They've ran tests. Turn off the sound, discharge me.. and within 24 hrs it's going off again. They said it was not my battery yet. I still had 18 months or so. And they really didn't know . I'm tired of going and getting admitted for the same crap every time.
My heart raced so fast I passed out and fell flat on my face. After some tests at the hospital it was determined the reason for passing out was my heart raced uncontrollably to fast. I had a heart attack in 2012 and this happened in 2014. It's been well controlled since then with an implanted defibrillator.