This is a special type of pacemaker that helps the heart beat in a more organized way. It has leads that go into the heart muscle to coordinate the contractions of both the upper and lower chambers. It's used to help people with certain heart rhythm problems.
Every report comes from a Lived member, sent anonymously.
Have you tried Biventricular Pacemaker for Heart Failure?
A biventricular pacemaker is an implanted device that helps the two lower chambers of the heart (the ventricles) squeeze at the same time. Doctors call this treatment cardiac resynchronization therapy, or CRT. It is used mainly for heart failure, in which the heart cannot pump enough blood for the body's needs. In many people with heart failure, the electrical signal that triggers each heartbeat travels too slowly through the left side of the heart. The most common cause is left bundle branch block, a delay in one of the heart's main wiring pathways. The wall between the ventricles then contracts early and the outer wall of the left ventricle contracts late, so part of each beat's effort is wasted and a weak heart pumps even less efficiently. Over time this uncoordinated pumping can strain the heart further. A biventricular pacemaker sends small, painless electrical pulses through thin wires (leads) to both ventricles at once, and usually also senses the upper chamber so the timing of each beat stays natural. Restoring a coordinated squeeze lets the same heart muscle move more blood with each beat. Some devices also include a defibrillator, which can deliver a shock to stop a dangerous fast rhythm; these are called CRT-D, while pacing-only devices are called CRT-P.
CRT is meant for a specific group of people with heart failure, identified by two tests. An echocardiogram (an ultrasound of the heart) measures the ejection fraction, the share of blood the left ventricle pushes out with each beat; a healthy heart pumps out roughly half or more. An electrocardiogram (ECG) shows how long the electrical signal takes to spread through the ventricles, called the QRS duration. A long QRS means the ventricles are being activated out of step. The clearest candidates still have heart failure symptoms, such as breathlessness or fatigue with ordinary activity, despite well-adjusted heart failure medicines, have an ejection fraction of 35% or less and have left bundle branch block. People with other kinds of electrical delay can also benefit, mainly when the QRS is markedly prolonged (150 milliseconds or longer). CRT may also be chosen for someone with reduced pumping function who needs a pacemaker for a slow heartbeat and would otherwise be paced from the right ventricle alone, since that kind of pacing can itself make the ventricles contract out of step. Atrial fibrillation (an irregular rhythm in the upper chambers) does not rule CRT out, but the device must pace nearly every beat to help, because the heart's own irregular beats are not coordinated. It is not a general treatment for every weak heart. It is not recommended as the first choice for a slow heart rate when pumping function is normal, and there is little evidence of benefit when the QRS is narrow or when right bundle branch block (a delay in the right-side pathway) is the only electrical problem. Whether a CRT-D or CRT-P is chosen depends largely on the person's risk of dangerous fast rhythms and their overall health and goals.
The device is implanted by a cardiac electrophysiologist (a heart rhythm specialist) in a minor surgical procedure, not open-heart surgery. The doctor makes a small cut below the collarbone, guides two or three leads through a vein into the heart using X-ray imaging, and places the small battery-powered generator in a pocket under the skin. The lead for the left ventricle is the trickiest part: it is threaded into a vein on the outer surface of the heart, and sometimes a suitable position cannot be found on the first attempt. A newer approach, conduction system pacing, places a single lead in the wall between the ventricles to stimulate the heart's own wiring directly. It is increasingly used as an alternative or add-on to standard biventricular pacing, and the specialist may discuss which approach fits. Many people stay in the hospital overnight. Before discharge the team checks the leads with an X-ray, confirms the device settings and sets up remote monitoring, in which a home transmitter sends device data to the clinic. You receive an ID card with the device details to carry at all times.
At first you are typically asked to avoid heavy lifting, intense activity and lifting the arm above your head, so the new leads stay in place, and not to drive for at least a week. Most people return to everyday activities within a few days. When CRT works well, breathlessness and fatigue gradually ease and exercise tolerance improves over weeks to months, and the heart's pumping function may strengthen as it remodels. Responses vary widely. In one large study, about 45% of people had a meaningful improvement in ejection fraction (a gain of 5 to 20 points), about 18% improved dramatically (more than 20 points), and about 37% had little or no change. Heart failure medicines continue alongside the device either way. Follow-up is long term. The first device check is often about a month after implant, then every 6 to 12 months, with remote monitoring in between. An echocardiogram 3 to 12 months after implant shows how the heart has responded, and settings can be adjusted to improve pacing. Because these devices pace constantly, the battery runs down sooner than in a standard pacemaker, and the generator is replaced in a shorter procedure every several years. If you have a CRT-D, low-energy pacing to stop a fast rhythm may feel like a flutter or nothing at all, but a full shock feels like a sudden, strong jolt. After one or two shocks, if you feel well afterward, contact your care team to be checked that day or the next. If you do not feel well after a shock (for example, chest pain, trouble breathing or fainting), or you have several shocks in a short period, call 911. A shock also affects when you can legally drive, so ask your team about the rules where you live.
For people with symptomatic heart failure, reduced ejection fraction and a wide QRS, CRT is supported by several large randomized trials. When the device was switched on rather than off, people walked farther in a six-minute test, had fewer symptoms, reported better quality of life and had stronger pumping function. In a pooled analysis of five trials with nearly 3,900 patients followed for about two years, 13.7% of those with biventricular pacing died compared with 20.8% of those treated with medicines or a defibrillator alone. In one of these trials, hospitalization for heart failure fell from 33% to 18% compared with medicines alone. Benefit is concentrated in people with left bundle branch block and a long QRS. It is less certain with other electrical patterns, very mild symptoms or a narrow QRS, and it varies even among good candidates. Conduction system pacing is a promising alternative: small trials and observational studies suggest it may match or improve on biventricular pacing for some people, but results have been inconsistent and larger trials are still under way.
Implanting a CRT device is generally safe, but about 6 to 8 in 100 people have a procedure-related problem. The most common is a lead that moves out of position or breaks, which may need a second procedure. Other problems include bleeding or a blood collection in the device pocket, infection and, less often, a collapsed lung. Occasionally the pacing stimulates nearby muscles, causing twitching, which may need the settings or a lead adjusted. Complications are more frequent with a CRT-D than with a pacing-only device, and every later generator replacement carries its own small risk, including infection. Call your care team right away if you have a fever, chills, or increasing pain, redness or swelling at the device site, including months after the procedure, because a device infection can spread and is serious. Also call promptly if you feel newly dizzy, faint or short of breath, which can mean the device is not working properly. Daily life involves a few precautions. Keep cell phones, headphones and other magnets about 6 inches from the device, and avoid strong electrical or industrial equipment. Most household appliances are fine. Always tell doctors and dentists about the device, since MRI scans, surgical cautery, radiation therapy and some other procedures may require special settings or a different approach. Living with a CRT-D can also bring anxiety about shocks, which is worth raising with your team. If health declines or priorities change, the shock function can be switched off without surgery while pacing continues.
Last reviewed • Oct 2026
Educational content, not medical advice.
Share your experience with Biventricular Pacemaker, what's helped you, or ask the community a question.